- CAT IV 600V and CAT III 1000V
- 6000 count 2.8” TFT Colour LCD display
- Built-in Thermal imager with MIN/MAX
- 50Hz fast Thermal image frame rate
- DC voltage 1000V and AC Voltage 1000V
- AC, AC+DC TRMS Voltage 1000V
- DC Current 10A
- AC Current 10A
- Resistance 60Mꭥ
- Capacity 6mF
- Frequency 10MHz
- Duty Cycle 95%
- K-Type Temperature Range: -40 to 600˚C
- Thermal Temperature Range: -20°C to 260°C
- Flexible Coil AC Current 3000A
- Diode Test and Continuity
1000V AC/DC True RMS Thermal Multimeter
Description
The MT2005 Pro True RMS Industrial DMM combines a thermal imager, precise A/D conversion, and Bluetooth BLE for swift problem-solving in production gear. Its double-molded plastic body ensures safety with an IP65 waterproof rating.
Specifications
| Function | Range | Resolution | Accuracy |
| Multimeter Function | |||
| DC voltage | 600.0mV – 1000V | 0.1mV | ± (0.09% + 5 Digits) |
| AC voltage | 600.0mV – 1000V | 0.1mV | ± (0.8% + 5 Digits) |
| AC + DC TRMS voltage | 6.000V – 1000V | 0.001V | ± (2.4% + 20 Digits) |
| DC Current | 600.0μA – 10A | 0.1μA | ± (0.9% + 5 Digits) |
| AC Current | 600.0μA – 10A | 0.1μA | ± (01.2% + 5 Digits) |
| Flexi Coil AC Current | 30.00A – 3000A | 0.01A | ± (0.8% + 5 Digits) |
| Duty Cycle | 5.0% to 95.0% | 0,001 | ± (1.2% + 2 Digits) |
| Resistance | 600.0Ω – 60MΩ | 0.1Ω | ± (0.5% + 5 Digits) |
| Frequency | 40.00Hz -10MHz | 0.01Hz | ± (0.09% + 5 Digits) |
| Capacitance | 60.00nF – 6mF | 0.01nF | ± (1.2% + 8 Digits) |
| Temperature | -40 – 600°C | 0.1°C | ± (3°C or ± 3%) |
| Continuity | Yes | ||
| Diode test | Yes | ||
| True RMS Measurements | AC, AC+DC | ||
| AC Bandwidth | 50Hz to 100KHz | ||
| Digital Display | 6000 count 2,8″ TFT | ||
| Bargraph | Yes | ||
| Bluetooth | BLE 4.0 | ||
| Records events and Trends | Yes | ||
| Data logging | Yes | ||
| Thermal Imaging Functions | |||
| Thermal Measurement | |||
| Temperature | -20°C – 260°C | ± (3°C or ± 3%) | |
| Imaging and Optical Data | |||
| Field of View | 21° x 21°/0.5m | ||
| Spatial resolution (IFOV) | 4.53mrad | ||
| Thermal sensitivity/NETD | <0.1°C @ +30°C/100mK | ||
| Image Range | 50Hz | ||
| Focus mode | Focus free | ||
| Zoom | 1 x 32 x continuous, digital zoom | ||
| Focal Length | 7.5mm | ||
| Focal Plane Array (FPA) / Spectral range | uncooled microbolometer / 8-14μm | ||
| IR Resolution | 80 x 80 | ||
| Image Presentation | |||
| Display | 2.8″ LCD, 240 x 320 pixels | ||
| Image Modes | IR Image, Visual image, | ||
| Colour Pallets | Iron, rainbow, rainbow HC, grey, grey inverted | ||
| Measurement analysis | |||
| Spot | Centre spot | ||
| Automatic hot/cold detection | Hot or cold markers | ||
| Emissivity correction | Variable 0.01 to 0.99 | ||
| Measurement corrections | Emissivity, reflected temperature | ||
| Data Communications Interfaces | |||
| Interfaces | Bluetooth BLE | ||
Safety Ratings